Covariance: sub-01_task-audiovisual_cov.fif (n_samples: 65999)
Singular values of the noise covariance
Epochs: sub-01_task-audiovisual_epo.fif
Epochs: sub-01_task-audiovisual_proc-clean_epo.fif
Evoked: sub-01_task-audiovisual_ave.fif (0.50 * Auditory/Left + 0.50 * Auditory/Right)
Topomap (ch_type = grad)
Topomap (ch_type = mag)
Evoked: sub-01_task-audiovisual_ave.fif (0.50 * Visual/Left + 0.50 * Visual/Right)
Topomap (ch_type = grad)
Topomap (ch_type = mag)
Evoked: sub-01_task-audiovisual_ave.fif (Auditory/Left)
Topomap (ch_type = grad)
Topomap (ch_type = mag)
Evoked: sub-01_task-audiovisual_ave.fif (Auditory/Right)
Topomap (ch_type = grad)
Topomap (ch_type = mag)
Evoked: sub-01_task-audiovisual_ave.fif (1.000 × 0.50 * Visual/Left + 0.50 * Visual/Right + -1.000 × 0.50 * Auditory/Left + 0.50 * Auditory/Right)
Topomap (ch_type = grad)
Topomap (ch_type = mag)
Evoked: sub-01_task-audiovisual_ave.fif (1.000 × Auditory/Right + -1.000 × Auditory/Left)
Topomap (ch_type = grad)
Topomap (ch_type = mag)
Evoked: sub-01_task-audiovisual_ave.fif (GFPs)
Evoked: sub-01_task-audiovisual_ave.fif (GFPs)
Forward: sub-01_task-audiovisual_fwd.fif
Forward | MEG channels: 306 | EEG channels: 0 | Source space: Surface with 7394 vertices | Source orientation: Free
Inverse: sub-01_task-audiovisual_inv.fif
InverseOperator | MEG channels: 306 | EEG channels: 0 | Source space: surface with 7394 sources | Source orientation: Free
Raw: sub-01_task-audiovisual_run-01_proc-filt_raw.fif
| Measurement date | August 16, 1921 GMT |
|---|---|
| Experimenter | mne_anonymize |
| Digitized points | 146 points |
| Good channels | 102 magnetometer, 204 gradiometer, and 0 EEG channels |
| Bad channels | |
| EOG channels | EOG 061 |
| ECG channels | Not available |
| Measurement time range | 42.96 to 320.67 sec. |
| Sampling frequency | 600.61 Hz |
| Highpass | 1.00 Hz |
| Lowpass | 40.00 Hz |
PSD
Raw: sub-01_task-audiovisual_run-01_proc-sss_raw.fif
| Measurement date | August 16, 1921 GMT |
|---|---|
| Experimenter | mne_anonymize |
| Digitized points | 146 points |
| Good channels | 102 magnetometer, 204 gradiometer, and 0 EEG channels |
| Bad channels | |
| EOG channels | EOG 061 |
| ECG channels | Not available |
| Measurement time range | 42.96 to 320.67 sec. |
| Sampling frequency | 600.61 Hz |
| Highpass | 0.10 Hz |
| Lowpass | 172.18 Hz |
PSD
SSP Projectors: sub-01_task-audiovisual_proj.fif
Trans: sub-01_task-audiovisual_trans.fif
BEM
-
Slice axial 0
-
Slice sagittal 0
-
Slice coronal 0
Run 01
Run 01
Events in filtered continuous data
Condition: Auditory
0.50 * Auditory/Left + 0.50 * Auditory/Right
Condition: Visual
0.50 * Visual/Left + 0.50 * Visual/Right
Condition: Auditory/Left
Auditory/Left
Condition: Auditory/Right
Auditory/Right
Contrast: Visual – Auditory
1.000 × 0.50 * Visual/Left + 0.50 * Visual/Right + -1.000 × 0.50 * Auditory/Left + 0.50 * Auditory/Right
Contrast: Auditory/Right – Auditory/Left
1.000 × Auditory/Right + -1.000 × Auditory/Left
Time-by-time Decoding: Visual ./. Auditory
143 × Visual ./. 144 × Auditory
Time-by-time Decoding: Auditory/Right ./. Auditory/Left
72 × Auditory/Right ./. 72 × Auditory/Left
Coregistration
Condition: 0.50 * AuditoryLeft + 0.50 * AuditoryRight
0.50 * Auditory/Left + 0.50 * Auditory/Right
Condition: 0.50 * VisualLeft + 0.50 * VisualRight
0.50 * Visual/Left + 0.50 * Visual/Right
Condition: AuditoryLeft
Auditory/Left
Condition: AuditoryRight
Auditory/Right